How to set maxcc in jcl

WebJul 10, 2024 · The following requirements can be met using below mentioned JCL utilities: 1. Need to check if a data set is empty or not. If it’s empty I want to skip all other steps. 2. Need to skip certain steps in my job if the input is empty. This would be easiest if a utility would generate a non-zero RC if the input is empty. 3. WebThe purpose of the IDCAMS step would be to delete the dataset. The IDCAMS DELETE command will give you a bad return code (12, if memory serves) if the dataset doesn't exist, but you can modify that by coding IF MAXCC=12 THEN SET MAXCC=0 under those circumstances. Update per additional restrictions on what's allowed

Using the SET command and MAXCC Parameter - IBM

WebJan 29, 2010 · Condition Codes (sometimes called Return Codes) are simply a method to let the caller know how the program ended. The program itself sets the COND CODE prior to ending. The degree of severity for certain errors conditions are typically related to the rising COND CODE. 0 = OK 4 = Informational 8 = Warning 12 = Error 16 = Severe error WebExplanation: In this example, After STEP01 is completed we check the Return code of STEP01 step. if return code is zero then STEP02 step will execute else step STEP03 will be executed. Tips: IF RC = 0 THEN IF STEP1.RC < 12 THEN If you not given the stepname, then the highest return code from all job steps is taken for checking. gotham knights csfd https://theprologue.org

Setting MAXCC in JCL using IDCAMS mainframegeek

WebMy requirement here is to set the Maxcc=0 if the FTP is successful in either of the three steps. I have already tried the below piece of code:- if ( step020.RC =0 step030.RC =0 … WebIf you have CA-DISK: //DMS EXEC DMS SCAN REALVOLS SELECT SGNAME=/,CRIT=(CATSTAT,NE,OK) *not-cataloged and incorrectly cataloged datasets.* WebUse the SETRC function to set the job step return code to a specified value. Use conditional parameters to set the return code based on an existing return code value. Syntax .-IFOP=EQ-. >>-SETRC--RC=rc--+---------+--+----------+--------------------->< +-IFOP=GE-+ '-IFRC=rc2-' gotham knights crashing xbox

setting maxcc conditionally in jcl -IBM Mainframes

Category:Top VSAM Interview Questions and Answers (2024) - InterviewBit

Tags:How to set maxcc in jcl

How to set maxcc in jcl

About MAXCC codes - JCL - IBM Mainframe Forum

WebUsing the SET command and MAXCC Parameter In this example, if the maximum condition code is 0, the program lists an entry from a catalog and prints a data set. If the maximum condition code is not 0, set the maximum condition code to 8. IF MAXCC=0 THEN DO LISTCAT CATALOG (AMASTCAT/MST27) ENT (MN01.B005) PRINT INFILE (AJK006) END WebNov 9, 2024 · Next, you want to automatically copy your four JCL job PDS members residing on z/OS as .txt files and place those files on your local machine. In this case, you'll use FTP. Place the following lines into a .txt file (let’s call the file SampleFTP.txt) and place the file on your desktop (or, for that matter, anywhere on your local Windows ...

How to set maxcc in jcl

Did you know?

WebMay 12, 2009 · maxcc=12 while using IEBGENER by weishi » Tue May 12, 2009 5:47 am Hi, when I used IEBGENER to copy a PS, maxcc=12,but the data set was copied and no errors encountered, I want to know the reasons,thanks. my jcl: Select all //QR115 JOB ,'QR115',MSGLEVEL= (1,1),MSGCLASS=A, // CLASS=A,NOTIFY=QR115 … WebThe SET command may be used to set either the LASTCC value or the MAXCC value to a specific value. Frequently the SET command is used to reset the return code (s) to a value of 0 following an expected warning level error condition. Example: Let us see an example how to delete and define VSAM dataset in single JCL step using IF statement.

WebMay 9, 2012 · So you have a DELETE - it is returning a code of 8 - probably because the dataet to be deleted does not exist. It does not exist - you were trying to delete it - no problem so set the return code to 0 (SET MAXCC+0) and continue with the next operation. If you want to stop the 8 happening in the first place then you need to define a dataset to ... WebMay 13, 2011 · How to setup MAXCC of JCL using IDCAMS? You just need to code SET MAXCC= in the SYSIN dataset of IDCAMS. What are the limits for SET MAXCC command of IDCAMS You can use any value as return code from 0 to 16, all the values out of this range will cause a MAXCC 16 for the JCL Sample JCL to set MAXCC d ===&gt; Scroll …

WebThanks Varun. Is there any other utilities to determine this? -----Original Message----- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Varun Manocha Sent: Tuesday, February 26, 2008 4:34 PM To: [email protected] Subject: Re: How to find uncatalog datasets.Mani, I use a JCL as below : //STEP01 EXEC … WebJul 7, 2005 · The command SET MAXCC = x is used to override internal return code of IDCAMS. Really there are two Retrun code in IDCAMS that are LASTCC and MAXCC, but …

WebJun 23, 2024 · If one of the data sets isn't there, you can suppress the CC 8 by using an IF LASTCC = 8 after the DELETE or IF MAXCC = 8 as the last card. (Note that 8 can be returned for other reasons other than not in catalog.)

WebMay 10, 2024 · The solution is to add an IDCAMS step at the end of your jobs JCL, use a LISTC ENT on a dummy dataset and set the MAXCC to 0000. Then add to the jobcard, JOBRC=LASTRC which instructs the job to use the last return code of the job to set the jobs final return code. In this case, it will be zeros as instructed by the IDCAMS. gotham knights crossplay pc xboxWebUsing the SET command and MAXCC Parameter z/OS DFSMS Access Method Services Commands SC23-6846-01 In this example, if the maximum condition code is 0, the program lists an entry from a catalog and prints a data set. If the maximum condition code is not 0, … chiew kim boon \\u0026 sons sdn bhdWebThe purpose of the IDCAMS step would be to delete the dataset. The IDCAMS DELETE command will give you a bad return code (12, if memory serves) if the dataset doesn't … gotham knights crossplay redditWebMay 23, 2011 · But, my requirement is that, "no record found" situation is acceptable and the job has to end with RC 0. I tried the below code: //STEP01 EXEC PGM=FILEAID ..... .... // IF STEP01.RC = 8 THEN //STEP02 EXEC PGM=IDCAMS //SYSPRINT DD=* SET MAXCC = 0 // ENDIF Although STEP02 was executed the RC from the job was 8. Please advice. … chiew-lan taiWebWhen we want to submit a JCL(JOB), we give the command ‘SUB’ or ‘SUBMIT’. ... MAXCC=0000 CN(INTERNAL). If you notice, we can get MAXCC=00 or 04 or 08 or 12 or 16 etc. MAXCC is maximum condition code which is the maximum return code from any step. Return code is the status of each step. Follow @tutorial_brain. Various Return codes of … chiewich outdoor floor matWebsets. nnbegins with 01 and increases by 1 up to a maximum of 16. SORTOFnnis used by the OUTFIL statement. Program Control Statements The program control statements supported by MFJSORT are listed below, together with any restrictions. The rules for coding the statements are identical to the mainframe utility. chie winter uniformWebSYS1.IMAGELIB data set open with the IMGLIB macro when checkpoint taken. Programmer Response: Ensure that all IMAGELIB DCBs are closed prior to issuing CHKPT. See also IMGLIB. 251: S23F: A data set that was not a checkpoint data set at checkpoint time was found to be open as a secure checkpoint data set at restart time. chie wig on cell phone